Nouveau PRO ECO 120W 24V 5A weidmueller Bloc d'alimentation, bloc d'alimentation à découpage, 24 V N° de commande : 1469480000

Nouveau PRO ECO 120W 24V 5A weidmueller Bloc d'alimentation, bloc d'alimentation à découpage, 24 V N° de commande : 1469480000

€59.11
  • Description
  • Commentaires
  • Expédition et retours

Manufacturer : Weidmueller

Version : Power supply, switch-mode power supply unit, 24 V

Order No. : 1469480000

Type : PRO ECO 120W 24V 5A

GTIN (EAN) : 4050118275476

Qty. : 1 pc(s).

Depth : 100 mm

Depth (inches) : 3.937 inch

Height : 125 mm

Height (inches) : 4.921 inch

Width : 40 mm

Width (inches) : 1.575 inch

Net weight : 675 g

Storage temperature : -40 °C...85 °C

Operating temperature : -25 °C...70 °C

AC current consumption : 1,26 A @ 230 V AC / 2,24 A @ 110 V AC

AC input voltage range : 85...264 V AC (derating at 100 V AC)

Connection system : Screw connection

DC current consumption : 0,39 A @ 370 V DC / 1,16 A @ 120 V DC

DC input voltage range : 80...370 V DC (Derating @ 120 V DC)

Frequency range AC : 47...63 Hz

Input frequency : 47...63 Hz

Input fuse (internal) : Yes

Inrush current : max. 40 A

Nominal power consumption : 137.9 VA

Recommended back-up fuse : 4 A / DI, safety fuse
6 A, Char. B, circuit breaker
3...5 A, Char. C, circuit breaker

Surge protection : Varistor

Capacitive load : unrestricted

Connection system : Screw connection

Continous output current @ UNominal : 5 A @ 55 °C, 3,75 A @ 70 °C

Nominal output current for Unom : 5 A at 55 °C

Output power : 120 W

Output voltage, max. : 28 V

Output voltage, min. : 22 V

Output voltage, note : (adjustable via potentiometer)

Overload protection : Yes

Parallel connection option : yes, max. 5

Protection against inverse voltage : Yes

Ramp-up time : ≤ 100 ms

Rated output voltage : 24 V DC ± 1 %

Residual ripple, breaking spikes : < 50 mVPP @ 24 V DC, IN

AC failure bridging time @ Inom : > 80 ms @ 230 V AC / > 20 ms @ 115 V AC

Degree of efficiency : 87 %

Earth leakage current, max. : 3.5 mA

Housing version : Metal, corrosion resistant

Indication : Green LED (Uoutput > 21.6 V DC), Yellow LED (loutput > 90 % IRated typ. ), red LED (overload, overtemperature, short-circuit, Uoutput < 20.4 V DC)

Max. perm. air humidity (operational) : 5 %…95 % RH

According to Standard : SN 29500

Operating time (hours), min. : 2.1 Mh

Ambient temperature : 25 °C

Input voltage : 230 V

Output power : 120 W

Duty cycle : 100 %

According to Standard : SN 29500

Operating time (hours), min. : 1 Mh

Ambient temperature : 40 °C

Input voltage : 230 V

Output power : 120 W

Duty cycle : 100 %

Mounting position, installation notice : on terminal rail TS 35

Operating temperature : -25 °C...70 °C

Power factor (approx.) : > 0.5…230 V AC / > 0.53…115 V AC

Power loss, idling : 4 W

Power loss, nominal load : 15 W

Protection against over-heating : Yes

Protection against reverse voltages from the load : 30…35 V DC

Short-circuit protection : Yes

Conductor cross-section, AWG/kcmil , max. : 12 

Conductor cross-section, AWG/kcmil , min. : 26 

Conductor cross-section, flexible , min. : 0.5 mm²

Conductor cross-section, rigid , max. : 6 mm²

Conductor cross-section, rigid , min. : 0.5 mm²

Connection system : Screw connection

Wire connection cross section, flexible (input), max. : 2.5 mm²

Contact load (NO contact) : max. 30 V DC / 1 A

Floating contact : Yes

Relay on/off : Output voltage >21.6 V DC/ <20.4 V DC, overload

Shipping Weight : 2 Kg

Choisissez un classement pour cet article. 1 étoile est le pire et 5 étoiles est le meilleur.

* délai de livraison.
Nous avons besoin de 1 - 2 jours pour traiter votre commande avant l'expédition. Il existe deux méthodes d'expédition. Livraison rapide: le délai de livraison pour les États - Unis et les pays européens prend 3 - 5 jours. Livraison lente: le délai de livraison pour les États - Unis et les pays européens prend 10 - 15 jours.
* Informations de suivi.
Après l'expédition de notre colis, le client reçoit automatiquement un e - mail avec les détails de suivi.
* politique sur les colis perdus.
Si le colis n'arrive pas dans les 4 semaines suivant la date d'expédition, ce colis sera considéré comme perdu. Dans ce cas, un nouveau colis sera expédié au client tant que nous serons en mesure de fournir le même article que celui acheté par le client. Si nous ne sommes pas en mesure de fournir le même article pour remplacer l'article manquant, nous proposerons un article similaire au client ou rembourserons leurs frais, car cela sera convenu d'un commun accord par le client. Si un ou plusieurs articles qui ne sont ni identiques ni similaires ne peuvent pas être expédiés, le client peut demander l'annulation complète de la commande, de sorte que le coût total de la commande, y compris les frais d'expédition et de manutention, sera intégralement remboursé.